Static Groove Spec Table

Static Groove KS Specifications — 5 sizes
JIS B 2401

This specification follows JIS (Japanese Industrial Standards). JIS is highly compatible with Korean KS standards and is essential when sourcing or maintaining Japanese-manufactured parts and equipment.

O-ring groove dimensions for static seal applications such as flanges and covers.

Practical Notes

  • Apply 15–30% compression — higher than dynamic type. Surface roughness Ra 0.8–1.6μm — less stringent than dynamic grooves.
  • Bolt holes near O-ring grooves can deform sealing surfaces. Maintain minimum distance between groove and bolt holes.

Selection Guide

Groove dimensions for static sealing at flanges and covers. Higher compression (15–30%) than dynamic type for seal reliability. Surface roughness Ra 0.8–1.6μm — less stringent machining than dynamic type.

JISStatic Groove

5 sizes
Wire/UseGroove DGroove WSqueezeNote-
CS1.9Static1.42.626%Flange/Bore-
CS2.4Static1.83.225%Flange/Bore-
CS3.1Static2.354.124%Flange/Bore-
CS3.5Static2.654.624%Flange/Bore-
CS5.7Static4.37.525%Flange/Bore-

Key Features

  • Static sealing only; O-ring remains stationary at flange/cover joint faces
  • Compression ratio 15–30%, higher than dynamic type, prioritizing seal reliability
  • Surface roughness Ra 0.8–1.6 μm acceptable; less stringent machining than dynamic type

Key Applications

Hydraulic manifold covers, pump housing joint faces, pipe flange seals, valve bonnets, pressure vessel manholes

FAQ

Difference between static and dynamic O-ring grooves?

Static: higher compression (15–30%), relaxed roughness (Ra 0.8–1.6μm). Dynamic: lower compression (8–16%) to minimize friction, smoother surfaces required.